Home > SHOP ALL PRODUCTS > Discountinued Products >

Instek GRS-6052A 50 MHz 2 Channels Real Time Analog and Digital Storage Oscilloscope. New in Box.

Instek GRS-6052A 50 MHz 2 Channels Real Time Analog and Digital Storage Oscilloscope. New in Box.
Instek GRS-6052A 50 MHz 2 Channels Real Time Analog and Digital Storage Oscilloscope. New in Box.


 
Discontinued product

Quantity in Stock:(Out of Stock)
Availability: Not available
Product Code: GRS-6052A

Description Application Notes
 
Features
Instek GRS-6052A 50 MHz 2 Channels Real Time Analog and Digital Storage Oscilloscope. New in Box.
 
The GRS-6000A Series is a Real-Time/Digital Storage Oscilloscope, which provides both analog and digital storage features in one product. When original signals are correctly represented and quickly updated, the GRS-6000A Series also allow simultaneously saving the waveform. With Equivalent Time Sampling at 500MSa/s, the GRS-6000A Series are capable of reconstructing repetitive waveforms up to 50MHz/30MHz in an accurate and detailed fashion. The waveform storage could be done just by pressing the RUN-STOP button, or through the Single Trigger mode which captures single-shot events. 10 Reference Waveforms can be saved and recalled for comparing waveforms. Numerous functions such as Average, Pre-Trigger, Roll mode, Peak Detect, Envelop, Persistence, and X-Y mode are available to fit in various measurement applications. The RS-232C Interface and the free Remote Control Software enable monitoring, remote controlling, and storing waveforms in PC.
 
FEATURES
  • DC~50MHz Bandwidth, 100MSa/s, 2kW/CH x 2
  • Equivalent Time Sampling of 500MSa/s max.
  • Acquire Mode : Peak Detect, Envelop, Persistence
  • Pre-Trigger Function 0 ~ 10 div
  • ROLL Mode to 100s/div
  • Waveform SAVE/RECALL 10 sets (REF0~REF9)
  • Averaging Function (2 ~ 256)
  • Smoothing Function ON/OFF
  • Max. Sweep Rate 10ns/div
  • ALT-MAG Function (x5, x10, x20)
  • Cursor Readout Function: V, T, 1/ T
  • Panel Setting SAVE/RECALL 10 sets (M0~M9)
  • VERT Mode Triggering
  • RS-232C Interface
  •  
    SPECIFICATIONS

    CRT

    Type and Acceleration
    6-inch CRT, 10kV
    Illumination Front panel control
    Z-axis Input Sensitivity : at least 5V
    Polarity : positive going input decreases intensity
    Max. input voltage:30V(DC+ACpeak)
    Input Impedance : approx. 33k

    VERTICAL SYSTEM

    Deflection Coefficient and Accuracy 1mV ~ 2mV/div }5%,
    5mV ~ 20V/div }3%,
    14 steps in 1-2-5 sequence
    Variable Continuity 2.5 : 1 ~ min. 50V/div
    Bandwidth (-3dB) 1mV ~ 2mV/div: DC~7MHz
    5mV ~ 20V/div: DC~50MHz
    Vertical Mode CH1, CH2, DUAL (ALT or CHOP)
    Chopper Frequency Approx. 250kHz
    Sum or Difference
    CH1+CH2, CH1-CH2
    Invert
    CH2
    Input Impedance
    1M }2%//approx. 25pF
    Input Coupling
    AC, DC, GND
    Input Voltage
    Max. 400V(DC+ACpeak)

    HORIZONTAL SYSTEM

    Sweep Time
    0.2s/div ~ 0.5s/div, 20 steps
    Variable Continuity 2.5 : 1 up to 1.25s/div (uncal.)
    Accuracy
    }3%, }5% at x5/ x10MAG. }8% at x 20MAG
    Sweep Magnification
    x5, x10, x20
    Max. Sweep Time 20ns/div (10ns/div uncal)
    ALT-MAG Function Yes
    HOLD-OFF Time Variable

    TRIGGER

    Trigger Mode
    AUTO, NORM, TV
    Trigger Source
    VERT, CH1, CH2, LINE, EXT
    Trigger Coupling AC, HFR, LFR
    Trigger Slope
    g+horg - hpolarity
    ALT Trigger
    Yes
    Indicator Trigger LED Yes
    TV Sync. Separator
    TV-Vg-h, TV-Hg - h
    Trigger Sensitivity
    GRS-6052A 20Hz~5MHz 5MHz~40MHz 40Hz~50MHz
    CH1, CH2 0.5div 1.5div 2.0div
    Vert-Mode 2.0div 3.0div 3.5div
    EXT 200mV 800mV 1V
    TV sync. pulse more than 1 div or 200mV (EXT)
    External Trigger Input
    Input impedance :Approx. 1M//25pF (AC coupling)
    Max. input voltage : 400V (DC + ACpeak)

    X-Y OPERATION

    Input
    X-axis : CH1 ; Y-axis : CH2
    Sensitivity 1mV/div ~ 20V/div
    Bandwidth X-axis : DC ~ 500kHz (-3dB)
    X-Y Phase Shift <3 from DC ~ 50kHz

    DIGITAL STORAGE

    Acquisition Digitizer
    8 bit ADC x 2
    Max. Sampling Rate
    500MSa/s for equivalent time sampling
    100MSa/s for normal sampling
    Storage Bandwidth Single shot: DC ~ 25MHz
    Repetitive: DC ~50MHz
    Dynamic Range }5div
    Memory Length- Acquisition Memory
    2k words/CH x 2, 1k words/CH(equivalent)
    Memory Length- Save REF Memory
    1k words/CH x 10 with back-up memory (REF0~REF9)
    Memory Length- Display Memory 1k words/CH x 4 waveform(max.)
    Sweep Time Equivalent: 0.2s/div ~ 0.5s/div
    Normal Sample: 1s/div ~ 0.1s/div
    Roll: 0.2s/div ~ 100s/div
    Sweep Magnification x 5, x 10, x 20
    Max.Sweep Time
    10ns/div
    MAG Interpolation DOTS, LINEAR
    ALT-MAG Function Yes
    Acquire Mode
    Sample, peak detect(>25ns), Envelop. Persist, Average(2~256)
    Operation Mode Auto, Norm, Single, Single-roll, Roll, X-Y, Run/Stop
    Smoothing Function Dot joint ON/OFF selectable
    Pre-Trigger
    Pre-trigger 0 ~10div in 0.02div steps
    X-Y Operation X-axis: CH1 Y-axis: CH2
    Storage Bandwidth DC~50MHz(-3dB)
    Display Resolution H: 100points/div; V: 25points/div;
    X-Y: 25 x 25 points/div
    SAVE/RECALL
    Panel Setting 10 sets(M0 ~M9)
    Waveform
    10 sets(REF0~REF9)
    READOUT & CURSOR
    Cursor Measurement V, T, 1/ T
    Readout Intensity
    Adjustable
    OUTPUT SIGNAL
    CH1 Signal Output Voltage : approx. 20mV/div (with 50 terminated)
    Bandwidth : 50Hz ~ 5MHz
    Calibrator Output
    Voltage : 0.5V}3%
    Frequency : approx. 1kHz, square wave
    INTERFACE
    RS-232C
    POWER SOURCE
    AC 100V/120V/230V}10%, 50/60Hz

    ACCESSORIES

    User manual x 1
    Power cord x 1
    GTP-060A-4 Probe (10:1/1:1) x 2
    DIMENSIONS & WEIGHT
    275(W) x 130(H) x 370(D) mm
    Approx. 8.5kg

    Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    SHOP ALL PRODUCTS
    SHOP ALL PRODUCTS > Discountinued Products