XFR is the smart choice for research, product development and production test applications such as R&D, magnet control, product design, ATE, process control, electroplating and burn-in. The unique features of XFR make it the best choice for OEM applications where high power and a wide adjustment of output voltage or current are required in a full 19-inch rack package. Choose from twenty 2800-watt and 1200-watt models.
Key Features
Electrical Specifications 1
Output Ratings:
Output Voltage
0-20 V
Output Current
0-60 A
Output Power
1200 W
Line Regulation: 2
Voltage (0.01% of Vmax + 2 mV)
2.5 mV
Current (0.01% of Imax + 2 mA)
4 mA
Load Regulation: 3
Voltage (0.02% of Vmax + 5 mV)
3 mV
Current (0.02% of Imax + 5 mA)
8 mA
Meter Accuracy:
Voltage (0.5% of Vmax + 1 count)
0.3 V
Current (0.5% of Imax + 1 count)
0.7 A
Output Noise & Ripple:
Voltage rms
8 mV
Voltage (p-p) (0-20 MHz)
50 mV
Current rms
300 mA
Drift (8 hours): 4
Voltage (0.05% of Vmax)
10 mV
Current (0.05% of Imax)
30 mA
Temperature coefficient: 5
Voltage (0.02% of Vmax/° C)
4 mV
Current (0.03% of Imax/° C)
18 mA
Program Slew Rate: 6
Rise Time
100 ms
Fall Time
OVP adjustment range: (5% to 110% of Vmax)
1-22 V
Efficiency: 7
81%
Interface Specifications 1,9
Program Resolution (16-bit):
Voltage
0.34 mV
Current
1.01 mA
OVP
Program Accuracy:
Voltage (0.2% + 10 mV)
75 mV (+/- 0.12%)
Current (0.3% + 10 mA)
250 mA (+/- 0.1%)
OVP (0.5% + 100 mV)
330 mV
Readback Resolution (16-bit):
Readback Accuracy:
Voltage (0.2% + 20 mV)
Current (0.3% + 20 mA)
1. Specifications indicate typical performance at 25 ° C +/- 5° C, nominal line input of 120 VAC.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage.
4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up.
5. Change in output per ° C change in ambient temperature, with constant line and load.
6. Measured with stepped 0-10 V analog programming source and a resistive load.
7. Typical efficiency at 100 VAC input voltage and rated output power.
8. Derate output current on 6 V model by 1.5 A per ° C for operating temperatures 30-50° C.
9. Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-60 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/- 0.12% of the set voltage of 10 volts.
General Specifications
Operational AC input voltage
85-130 VAC or 190-264 VAC 1 phase (17 A @ 120 VAC; 8.8 A @ 230 VAC typical), 47-63 Hz. Automatic range detect.
Switching Frequency
6 V to 40 V models: nominal 78 kHz (156 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz (125 kHz output ripple).
Time Delay
7 s maximum from power on until output stable
Voltage Mode Transient Response Time
<3 ms for output voltage to recover within 0.5 % of its rated voltage after a step change in load current of up to 10% to 90% of rated output
Maximum Voltage Differential
+/-600 VDC from output to safety ground
Remote On/Off and Interlock
2.5-15 V signal or TTL-compatible input, selectable logic
Remote Analog Programming
Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances;0-5 V, 0-10 V (default) voltage sources
Remote Analog Monitoring
Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output
Remote Programming and Monitoring Accuracy
1% zero to full scale output for the default range
Maximum Remote Sense Line Drop Compensation
5 V/line (Line drop is subtracted from total voltage available at supply output)
Operating Temperature Range
32° F to 122 ° F (0° C to 50° C)
Storage Temperature Range
-4° F to 158° F (-20° C to 70° C)
Humidity Range
Up to 90% RH, non-condensing
Front Panel Voltage and Current Control
10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution
0.02% of maximum voltage
AC Input Connector Type
3-terminal, 34 A/250 V, wire clamp connector with strain relief cover
Main Output Connector
6 to 40 V models: nickel-plated copper bus bars with bus bar shield; 60 V to 600 V models: 4-terminal wire clamp connector with strain relief
Weight (one unit)
18 lb (8.2 kg) approx
Dimensions (H x W x D)
1.7 x 19.0 x 20.0” (43.2 x 429.4 x 508.1 mm)
Options
GPIB-XFR1
GPIB Interface card (16-bit)
RS-232-XFR1
RS-232 Interface card (16-bit)
ISOL-XFR1
ISOL Interface card provides isolated analog control and readback
ISOL-420
4-20 mA isolated analog control
M13A
Locking knobs for front panel controls
Regulatory Approvals
CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; UL Listed to UL3111-1; CSA certified to CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.
Note: Specifications subject to change without notice.