Features
The ultimate tool for troubleshooting and maintenance
This thermal imager is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
IR-Fusion® Technology See things both ways—infrared and visual (visible light) images fused together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and fuses it together taking the mystery out of IR image analysis. IR-Fusion is standard on Ti10 models.
- Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
- Optimized for field use in harsh work environments.
- Engineered and tested to withstand a 2 m (6.5 ft) drop—When was the last time you dropped a tool?
- Withstands dust and water—tested to an IP54 rating.
- Delivers the clear, crisp images needed to find problems fast.
- Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
- Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
- Everything needed to get started is included.
- Adjustable hand strap for left-or right-handed use.
-
Manufactured in the U.S.A.
| Detailed specifications |
| Temperature |
| Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +250 °C (-4 °F to + 482 °F) |
| Accuracy |
± 5 °C or 5 % (whichever is greater) | |
| Imaging performance |
| Field of view |
23° x 17° |
| Spatial resolution (IFOV) |
2.5 mRad |
| Minimum focus distance |
Thermal lens: 15 cm (6 in) Visible (visual) light lens: 46 cm (18 in) |
| Focus |
Manual |
| Image frequency |
9 Hz refresh rate |
| Detector type |
160 X 120 focal plane array, uncooled microbolometer |
| Infrared lens type |
20 mm F = 0.8 lens |
| Thermal sensitivity (NETD) |
≤ 0.2 °C at 30 °C (200 mK) |
| Infrared spectral band |
7.5 μm to 14 μm |
| Visual camera |
640 x 480 resolution | |
| Image presentation |
| Palettes |
Ironbow, blue-red, high contrast, grey |
| Level and span |
Smooth auto-scaling and manual scaling of level and span |
| Minimum span (in manual mode) |
5 °C (9 °F) |
| Minimum span (in auto mode) |
10 °C (18 °F) |
| IR-Fusion® information |
Full infrared or picture-in-picture |
| Picture-In-Picture (PIP) |
100 % IR displayed in center 320 x 240 pixels |
| Full screen (PIP off) |
100 % IR displayed in center 640 x 480 LCD | |
| Image and data storage |
| Storage medium |
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images) |
| File formats |
Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files |
| Export file formats w/SmartView™ software |
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF | |
|
General specifications |
|
Temperature |
|
Operating: |
-10 °C to 50 °C (14 °F to 122 °F) |
|
Storage: |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries | |
|
Relative humidity |
|
|
10 % to 90 % non-condensing | |
|
Display |
|
|
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) | |
|
Controls and adjustments |
|
|
User selectable temperature scale (°C/°F) |
|
|
Language selection |
|
|
Time/Date set | |
|
Software |
|
|
SmartView™ full analysis and reporting software included | |
|
Power |
|
Battery: |
Internal rechargeable battery pack (included) |
|
Battery life: |
Three to four hours continuous use (assumes 50 % brightness of LCD) |
|
Battery charge time using ac adapter/charger and dc car charger: |
Two hours for full charge | |
|
AC operation/charging |
|
|
AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. | |
|
Power saving |
|
|
Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity | |
|
Safety standards |
|
CE Directive: |
IEC/EN 61010-1 2nd Edition Pollution Degree 2 | |
|
Electromagnetic compatibility |
|
EMC directive: |
EN61326-1 |
|
C-Tick: |
IEC/EN 61326 |
|
US FCC: |
CFR 47, Part 15 Class A | |
|
Vibration |
|
|
Shock |
|
|
25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides} | |
|
Dimensions (HxWxL) |
|
|
0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in) | |
|
Weight |
|
|
IP rating |
|
|
Warranty |
|
|
Calibration cycle |
|
|
Two-years (assumes normal operation and normal aging) | |
|
Supported languages |
|
|
English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese | |
| Model Name |
Description |
| Fluke Ti10 |
9 Hz Thermal Imager Thermal imaging camera w/ 20 mm lens.
Includes:
- AC power supply/battery charger (including mains adapters)
- SD memory card
- SD card reader (USB) for downloading images into your computer
- SmartView™ software with free software upgrades for life
- Rugged hard carrying case
- Soft transport bag
- Hand strap
- Users manual
- Warranty registration card
| | |
|
 |
| Batteries, Chargers & Adapters |
|
| Fluke TI-CAR CHARGER |
Fluke TI-CAR CHARGER | |
|