| Output Voltage |
|
0 to 35 VDC, Coarse and fine adjustment |
|
|
| Output
Current |
|
0 to 10A |
|
|
| Constant
Voltage Operation |
|
|
| Voltage
Regulation |
|
Line (108 - 132): <=0.2% + 2mV |
| Load
(no load to full load): <=0.04% + 2mV |
|
|
| Recovery
Time |
|
<=100us typical |
|
|
| Ripple
Voltage |
|
RMS <=1mV |
|
|
| Temperature
Coefficient |
|
0 °C to +40 °C <=300 PPM/°C |
|
|
| Constant
Current Operation |
|
|
| Adjustable
Current Limits |
|
5% to 100% |
|
|
| Current
Regulation |
|
Line: (108 - 132V) <=0.4% + 5mA |
| Load:
<=0.4% + 5mA |
|
|
| Current
Ripple |
|
<=3mA typical |
|
|
| Metering |
|
|
|
| Voltmeter |
|
|
|
|
|
| Range:
0 - 40V |
| Accuracy:
±2.5% |
|
|
| Amp
meter |
|
|
|
|
| Hi
Range: 0 to11A |
| Lo
Range: 0 to 2.2A |
| Accuracy:
±2.5% |
|
|
| Power
Requirements |
|
|
| Domestic |
|
|
120VAC ±10%, 60Hz |
|
|
| International |
|
120, 220, 230, 240 VAC, 50/60 Hz |
|
|
| Power
Consumption |
|
Approximately 560 Watts or Less at full load |
|
|
| Temperature
Range |
|
|
| Operation |
|
|
0 °C to +40 °C<=75% R.H. |
|
|
| Storage |
|
|
-15 °C to 70 °C<=85% R.H. |
|
|
| Dimensions
(H x W x D) |
|
5.7'' x 10.5'' x 15'' (145 x 267 x 381 mm) |